Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ulus Travma Acil Cerrahi Derg ; 21(3): 193-6, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26033652

RESUMO

BACKGROUND: Conduction disturbances including type 2 second-degree atrioventricular block (Mobitz II) and third-degree atrioventricular block following blunt chest trauma are probably rare. Moreover, the pathophysiological mechanisms responsible for this rare dysrhythmia following trauma are not well understood yet. In this study, it was aimed to identify the frequency of this dysrhythmia associated with trauma. METHODS: Two hundred and fifty-three consecutive Mobitz II block and third-degree atrioventricular block patients admitted to the Emergency Department of Internal Medicine between January 2012 and March 2013 were evaluated. Only four patients with Mobitz II block and third-degree atrioventricular block associated with trauma were enrolled into the present study. The level of atrioventricular block was defined according to electrocardiographic characteristics. RESULTS: Only four (mean age: 40.2±19.7 years, two male) of 253 patients were associated with trauma. All patients had normal coronary arteries in coronary angiography or multislice computed tomography. Permanent pacemaker was performed in two patients with third-degree atrioventricular block. None of the patients had coronary artery disease or hypertension. CONCLUSION: Rare clinical cases in the literature confirm that blunt chest trauma can cause conduction defects, which are usually transient. However, patients with blunt chest trauma must need an electrocardiographic evaluation for atrioventricular block upon admission and in the follow-up period.


Assuntos
Bloqueio Atrioventricular/diagnóstico , Traumatismos Torácicos/complicações , Ferimentos não Penetrantes/complicações , Adulto , Idoso , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Eletrocardiografia , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Marca-Passo Artificial , Índice de Gravidade de Doença , Turquia/epidemiologia , Adulto Jovem
2.
Anatol J Cardiol ; 15(4): 313-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25413228

RESUMO

OBJECTIVE: The effects of acute hemodialysis session on pulse wave velocity are conflicting. The aim of the current study was to assess the acute effects of ultrafiltration on the aortic mechanical properties using carotid-femoral (aortic) pulse wave velocity and pulse propagation time. METHODS: A total of 26 (12 women, 14 men) consecutive patients on maintenance hemodialysis (mean dialysis duration: 40.7±25.6 (4-70) months) and 29 healthy subjects (13 women, 16 men) were included in this study. Baseline blood pressure, carotid-femoral (aortic) pulse wave velocity, and pulse propagation time were measured using a Complior Colson device (Createch Industrie, France) before and immediately after the end of the dialysis session. RESULTS: While systolic blood pressure, diastolic blood pressure, mean blood pressure, pulse pressure, and pulse wave velocity were significantly higher in patients on hemodialysis than in healthy subjects, pulse propagation time was significantly higher in healthy subjects. Although body weight, systolic blood pressure, diastolic blood pressure, mean blood pressure, pulse pressure, and pulse wave velocity were significantly decreased, heart rate and pulse propagation time were significantly increased after ultrafiltration. There was a significant positive correlation between pulse wave velocity and age, body height, waist circumference, systolic blood pressure, diastolic blood pressure, mean blood pressure, pulse pressure, and heart rate. CONCLUSION: Although hemodialysis treatment may chronically worsen aortic mechanical properties, ultrafiltration during hemodialysis may significantly improve aortic pulse wave velocity, which is inversely related to aortic distensibility and pulse propagation time.


Assuntos
Aorta/fisiopatologia , Hemodiafiltração/instrumentação , Falência Renal Crônica/terapia , Adulto , Fatores Etários , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Tamanho Corporal , Estudos de Casos e Controles , Feminino , Humanos , Falência Renal Crônica/fisiopatologia , Masculino , Fluxo Pulsátil , Ultrafiltração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...